Command | |
---|---|
poweron | powers on the netra |
poweroff | powers off the netra |
reset | the same as the ok> reset command |
reset -x | resets the CPU only, externally initiated reset XIR |
break | goes to the ok> prompt from the OS- "Stop-a" |
environment | current status of all components in system |
check | updates component status after repairing it, run "lom> environment" again |
show eventlog | show last 10 events on the system |
set faulton | turns on the fault LED |
set faultoff | turns off the fault LED |
set alarmon [1-3] | sets 1 of 3 alarms on |
set alarmoff [1-3] | sets 1 of 3 alarms off |
show model | show the server model |
show hostname | same as uname -n |
show | help for the "show" command |
help | list of LOM commands |
bootmode -u | allows sharing of the console and LOM device |
bootmode normal | server boots using the OBP environment settings; must reset server to take effect |
bootmode forth | server stops at the "ok>" prompt- same as "Stop-f"; must reset server to take effect |
bootmode reset_nvram | ok> set-defaults" or "Stop-n"; must reset server to take effect |
bootmode diag | runs full POST: "ok> diag-switch? true" or "Stop-d"; must power off server and back on within 10 minutes |
bootmode skip_diag | ok> setenv diag-switch? false"; must power off server and back on within 10 minutes |