Link Monitor
(2023-11-15)
Example Link Monitor Configuration
config system link-monitor
edit "VLAN601"
set srcintf "VLAN601
set server "172.26.2.49"
set gateway-ip 172.26.2.49
set source-ip 172.26.2.50
set interval 1000
set failtime 15
set recoverytime 15
next
end
Example Link Monitor status
# diagnose sys link-monitor status
Link Monitor: VLAN-601, Status: dead, Server num(1), HA state: local(dead), shared(dead)
Flags=0x9 init log_downgateway, Create time: Tue Oct 24 21:48:10 2023
Source interface: VLAN-601 (75)
Source IP: 172.26.2.50
Interval: 1000 ms
Service-detect: disable
Diffservcode: 000000
Class-ID: 0
Peer: 172.26.2.49(172.26.2.49)
Source IP(172.26.2.50)
Route: 172.26.2.50->172.26.2.49/32, gwy(172.26.2.50)
protocol: ping, state: dead
Packet lost: 100.000%
MOS: 4.350
Number of out-of-sequence packets: 0
Recovery times(0/15) Fail Times(3/15)
Packet sent: 1898656, received: 1317, Sequence(sent/rcvd/exp): 63649/2789/2790